Home » Dent CON-0500-U Clamp-On CT 500A
Dent CON-0500-U Clamp-On CT 500A
Yes! It's in stock. 3 ready to ship
Yes! It ships today. 31 mins to order
Yes! Next day delivery available.
Yes! It ships today. 31 mins to order
Yes! Next day delivery available.
Price: $225.00




Clamp-on current transformers are the one-hand operating solution for
temporary or long-term studies. They are designed to work in tight
places and clamp around bus bars.
DENT’s energy monitoring components are used for a variety of applications, including building automation, tenant submetering, performance verification, energy management and new technology assessment.
DENT’s energy monitoring components are used for a variety of applications, including building automation, tenant submetering, performance verification, energy management and new technology assessment.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Current ranges include 10 to 600A AC
- Output Signal: 333 mV @ Maximum Input
- Working Voltage : 600Vrms
ELECTRICAL SPECIFICATIONS
Nominal Rating: 500A
Useful Current Range: 10 to 600A AC
Output Signal: .666 mV/A; 333mV @ 500A AC
Accuracy: 10 to 600A: ± 2.5% ± .6A; 48-440 Hz, 10 to 600A: ± 3.5% ± .6A; 440-1000Hz
Phase Shift: 10 to 600A < 3°
Frequency Range: 48 Hz to 1000 Hz
MECHANICAL SPECIFICATIONS
Dimensions: 19.5 x 6.6 x 3.4 cm (7.7 x 2.6 x 1.3”)
Maximum Cable/Bus Bar: Cable Diameter 3.0 cm (1.2”) Bus bar 6.3 x 0.5 cm (2.5” x 0.2”)
Polarity: Red lead is positive
Output Lead: Double insulated, 3 m (10 ft )
Operating Temperature: -10° to 55°C (14° to 120°F )
OTHER FEATURES
Jaw Opening: 3.3 cm (1.2”)
Weight: 350 g (12.3 oz)
Dielectric Strength: 6000V, 50/60 Hz between primary, secondary and the outer case of the handle 3000V 50/60 Hz between primary and secondary
Storage Temperature: -40° to +80°C (-40° to 175°F)
Case Protection: IP 40 (IEC 529)
Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38 mm of oak on concrete
Mechanical Shock: Test per IEC 68-2-6
Common Mode Voltage: 30 Vrms
SAFETY SPECIFICATIONS
Working Voltage: Maximum 600 Vrms
CE Mark: Extra insulation between electrical parts and handle; conforms to IEC 1010-2-032
Nominal Rating: 500A
Useful Current Range: 10 to 600A AC
Output Signal: .666 mV/A; 333mV @ 500A AC
Accuracy: 10 to 600A: ± 2.5% ± .6A; 48-440 Hz, 10 to 600A: ± 3.5% ± .6A; 440-1000Hz
Phase Shift: 10 to 600A < 3°
Frequency Range: 48 Hz to 1000 Hz
MECHANICAL SPECIFICATIONS
Dimensions: 19.5 x 6.6 x 3.4 cm (7.7 x 2.6 x 1.3”)
Maximum Cable/Bus Bar: Cable Diameter 3.0 cm (1.2”) Bus bar 6.3 x 0.5 cm (2.5” x 0.2”)
Polarity: Red lead is positive
Output Lead: Double insulated, 3 m (10 ft )
Operating Temperature: -10° to 55°C (14° to 120°F )
OTHER FEATURES
Jaw Opening: 3.3 cm (1.2”)
Weight: 350 g (12.3 oz)
Dielectric Strength: 6000V, 50/60 Hz between primary, secondary and the outer case of the handle 3000V 50/60 Hz between primary and secondary
Storage Temperature: -40° to +80°C (-40° to 175°F)
Case Protection: IP 40 (IEC 529)
Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38 mm of oak on concrete
Mechanical Shock: Test per IEC 68-2-6
Common Mode Voltage: 30 Vrms
SAFETY SPECIFICATIONS
Working Voltage: Maximum 600 Vrms
CE Mark: Extra insulation between electrical parts and handle; conforms to IEC 1010-2-032
Product brochures
Technical training
No user reviews available.





