| Specifications |
| Input Characteristics | | Input impedance | 1 MΩ, 20 pF | | Voltage rating | 600V rms, CAT III |
|
| V/A/Hz Display | | True-rms voltage (ac + dc) |
| | Ranges: | 5.000 V, 50.00 V, 500.0 V, 1250 V* | | Accuracy: | ±(1% + 10 counts) | | True-rms current (ac + dc) |
| | Ranges: | 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA | | Accuracy: | ±(1% + 10 counts) | | Frequency |
| | Ranges: | 10.0 to 15.0 kHz | | Accuracy: | ±(0.5% + 2 counts) |
|
| | CF Crest factor |
| | Ranges: | 1.0 - 10.0 | | Accuracy: | ±(5% + 1 count) |
|
| Power Display | | Watts, VA, VAR |
|
| 1-phase and 3-phase,3 conductor balanced loads | | Ranges: | 250 W - 1.56 GW | | Accuracy: | ±(4% + 4 counts) Fundamental Power | | Accuracy: | ± (2 % + 6 counts) Total Power | | PF Power Factor |
| | Range: | 0 - 1.0 | | Accuracy: | ±0.04 | | DPF Displacement Power Factor, Cos .F |
| | Range: | 0.25 - 0.9 | | Accuracy: | ±0.04 | | Range: | 0.90 - 1.0 | | Accuracy: | ±0.03 | | H2 Frequency Fundamental |
| | Ranges: | 40.0 to 70.0 Hz | | Accuracy: | ±(0.5% + 2 counts) |
|
| Harmonics Display | | Voltage, Current, Frequency |
| | Ranges: | Fundamental to 51st harmonic | | Accuracy: |
| | Fundamental: | VA ±(3% + 2 counts) W ±(5% + 2 counts) | | 2 to 31st harmonic: | VA ±(5% +3 counts) W ±(10% +10 counts) | | 32 to 51st harmonic: | VA ±(15% +5 counts) W ±(30% +5 counts) | | Frequency Fundamental |
| | Ranges: | 40 Hz to 70 Hz | | Accuracy: | ±0.25 Hz | | Phase Range: | V, A (between Fundamental & Harmonics) | | Accuracy: | ±3º to ±15º | | Range: | W (between Voltage Fundamental & Current Harmonics) | | Accuracy: | ±5º to ±15º | | K-factor (Current and Power) |
| | Range: | 1.0 to 30.0 | | Accuracy: | ±10% | | THD Total Harmonic Distortion |
| | Range: | 0.00 - 99.99 | | Accuracy: | ±(3% + 8 counts) |
|
| Sags and Swells | | Recording times: | 4 min to 16 days (selectable) | | Vrms Actual, Vrms max, min(AC + DC) |
| | Ranges: | 5.000V, 50.00V, 500.0V, 1250V* | | Accuracy: | Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts) | | Arms Actual, Arms max, min (AC + DC) |
| | Ranges: | 50.00A, 500.0A, 5.000 kA, 50.00 kA | | Accuracy: | ±(2% +10 counts) |
|
| Transient Capture | | Minimum pulse width: | 40 ns | | Useful bandwidth input 1: | DC to 1 MHz | | Number of transients: | 40 | | Voltage threshold settings: | 20%, 50%, 100%, 200% above or below reference | | Reference signal: | After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting. | | Vpeak min, Vpeak max at cursor: | 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale |
|
| R, C, Diode, Continuity | | Resistance ranges: | 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ | | Resistance accuracy: | ±(0.6% + 5 counts) | | Capacitance ranges: | 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF | | Capacitance accuracy: | ±(2% + 10 counts) | | Diode Ranges: | 0 to 3.000 V | | Diode voltage: |
| | Accuracy: | ±(2% + 5 counts) | | Continuity: | Beeper on at < 30 Ω ± 5 Ω | | Max current: | 0.5 mA | | Temperature: | °C or °F |
|
| Inrush Current | | Inrush times: | 1 s, 5 s, 10 s, 50 s, 100 s, 5 min | | Current ranges: | 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A | | Cursor readings: | A peak max at cursor 1 and cursor 2 | | Accuracy: | ±5% of full scale | | Time between cursors: | 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels) |
|
| Temperature (with accessory) | | Range: | -100 °C - 400 °C | | Accuracy: | ±(0.5% + 5 counts) |
|
| Scope Display | | Measurements: | dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor | | Time ranges: | 20 ns/div to 60 s/div | | Max sampling rate: | 25 MS/s | | Bandwidth |
| | Voltage channel [1]: | 20 MHz at inputs, 1 MHz with TL24 Leads | | Current channel [2]: | DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp | | Coupling: | AC, DC (10 Hz - 3 dB) | | Vertical sensitivity: | 5 mV/div to 500V/div | | Vertical resolution: | 8 bit (256 levels) | | Record length: | 512 samples per channel | | Base ranges: | 60 S/div to 20 nS/div ± (0.4% + 1 pixel) | | Timebase modes: | Normal, roll, single | | Pre-trigger: | Up to 10 divisions | | Trigger Source: | Input 1 or Input 2 or automatic selection | | Trigger Mode: | Automatic Connect-and-View™, Free Run, and Single Shot |
|
| | Connect-and-View™: | Advanced automatic triggering that recognizes signal patterns |
| Automatically adjusts triggering, timebase and amplitude and displays stable pictures |
|
| Memories |
| 20 (screens, settings, data) |
|
| Recording | | Recording times: | 4 min to 16 days (selectable) | | Parameters: | Choose one or two parameters from one of the groups below: |
| Volts/Ampères/Hertz | | Power: | Watts, VA, VAR, PF, DPF, Frequency |
| Harmonics, THD, Volts (Fund. & Harmonic), Ampères (F&H) Watts(F&H) |
| Frequency (H), %(H) of total, Phase(H), KF |
| Temperature | | Resistance: | Resistance, Diode, Continuity, Capacitance | | Scope: | DC Voltage, DC Current, AC Voltage, AC Current, Frequency, |
| Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor |
|
| Note |
| *Rated EN 61010-1 600 V CAT II CSA |
|