Home » Dent FLN-3000-B Flexible Current Transformer 3000A
Dent FLN-3000-B Flexible Current Transformer 3000A
Part Number:
DT FLN-3000-B
In Stock?
Stock may be available
please call (877)766-5412 to confirm
please call (877)766-5412 to confirm
Quantity
Price:
$519.00
USD (change)




The DENT Instruments 3000A Flexible Current Transformer is composed of
a flexible sensor and an electronic module. The flexible sensor permits
measurements on conductors where standard clamp-on current transformers
could not be used.
Specifically, it can be installed in tight spaces, or around breaker panels, cable bundles, wide or large bus bars and irregular shapes.
Unlike standard current transformers, this flexible CT does not use magnetic cores. The transformation principle is based on an air core. It presents virtually no load to the system under test, has a low phase shift and excellent frequency response. Additionally, it cannot be damaged by overloads.
The DENT 3000A Flexible Current Transformer is insensitive to DC current and measures only the AC component of the measured signal.
Specifically, it can be installed in tight spaces, or around breaker panels, cable bundles, wide or large bus bars and irregular shapes.
Unlike standard current transformers, this flexible CT does not use magnetic cores. The transformation principle is based on an air core. It presents virtually no load to the system under test, has a low phase shift and excellent frequency response. Additionally, it cannot be damaged by overloads.
The DENT 3000A Flexible Current Transformer is insensitive to DC current and measures only the AC component of the measured signal.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Measure from 10 Amps to 3000,
- Working voltage = 1000V rms max.,
- 36 inches in length,
- Accuracy = 1 % of reading,
- Remembers shape, allowing for pre-forming before use,
- Very low phase shift error,
- Dual range (switchable between 300A and 3000A),
- Output = 333mV at 300A or 3000A,
- Battery Life = 4000 hr's typical, 8000 hrs maximum.
MECHANICAL SPECIFICATIONS
Dimensions: 4.0 x 6.4 x 11.4 cm (1.56 x 2.5 x 4.5”)
Sensor: 90 cm long (35”)
Polarity: Positive terminal marked “1”
Output Lead: 3 m (10 ft) shielded cable
Operating Temperature: -10° to +55°C (14° to 131°F)
OTHER FEATURES
Cable Length: 2.0 m (6.5 ft) sensor to case
Weight: 370 g (13.8 oz)
Dielectric Strength: 5000 V around the case; 600 V rated leads
Storage Temperature: -20° to +70°C (-4° to 158°F)
Case Protection: Epoxy encapsulated housing
SAFETY SPECIFICATIONS
CE Mark: Double Insulation
Working Voltage: Maximum 600 Vrms
Dimensions: 4.0 x 6.4 x 11.4 cm (1.56 x 2.5 x 4.5”)
Sensor: 90 cm long (35”)
Polarity: Positive terminal marked “1”
Output Lead: 3 m (10 ft) shielded cable
Operating Temperature: -10° to +55°C (14° to 131°F)
OTHER FEATURES
Cable Length: 2.0 m (6.5 ft) sensor to case
Weight: 370 g (13.8 oz)
Dielectric Strength: 5000 V around the case; 600 V rated leads
Storage Temperature: -20° to +70°C (-4° to 158°F)
Case Protection: Epoxy encapsulated housing
SAFETY SPECIFICATIONS
CE Mark: Double Insulation
Working Voltage: Maximum 600 Vrms