Fluke 435-II Three Phase Power Quality Analyzer Kit

  • Predict, prevent, troubleshoot
  • Autotrend records what you see
  • New! Waveform capture
  • New! Energy loss calculator
  • New! Inverter efficiency
  • New! Includes 8GB of memory, software, carry case
  • Includes 4x 6000A flex CTs


Part Number:
FE 435-II
In Stock?
Yes! Available up to 2 units

Quantity

Price:
$7775.00 USD (change)

 

Shipping Information:

Ships in 1 - 2 Days
Arrives:
May 25-
May 31
Max of 2 units
$178.00
Fast: Ships today*
Arrives:
May 24
Max of 2 units
$250.00
Fastest: Overnight
Arrives:
May 23
Max of 2 units
$338.00

Fluke 435-II Series II Power Quality Analyzer

The Fluke 435-II is a Class A compliant three-phase power quality analyzer that help you locate, predict, prevent and troubleshoot problems in single phase and three phase power distribution systems. In addition to all the standard features of the Fluke 434-II, the Fluke 435-II offers additional features for the more demanding application.

The new 435-II offers most of the same measurement capabilities of the first generation of product:

  • Volts, Amps, Hz
  • Dips & Swells
  • Harmonics
  • Power & Energy
  • Unbalance
  • Monitor Mode
  • Inrush
  • Transients
  • Flicker
  • Mains Signalling
  • Event Capture

In addition, the new Fluke 435 Series-II also adds several great new features and capabilities.

New Flexible Wide Range Current Probes - the introduction of the new i430-TF ultra-thin flexible current probe offers 6000A range

Power Inverter Efficiency - measure the efficiency of conversion from DC to AC for renewable energy systems

Energy Loss Calculator - measure and put an estimated cost associated with the power loss that comes from phase unbalance and harmonics

PowerWave - measure and record voltage, current and frequency at high speed to monitor power quality problems associated with load switching

8MB -> 8GB of Memory - a removable SD memory card offers 10x the memory and is upgradeable to 32GB

Features:

  • Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
  • PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses.
  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places.
  • Automatic Trending: Every measurement is always automatically recorded, without any set-up.
  • System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
  • Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
  • View graphs and generate reports: With included analysis software.
  • Battery life: Seven hours operating time per charge on Li-ion battery pack.

PowerWave data capture
For some users, loads switching is a cause of power quality problems. When loads switch on, the current draw sometimes causes the voltage to drop to a level that causes other equipment to malfunction. The PowerWave function available in the 435 and 437 Series II models enables users to capture voltage, current and frequency signals simultaneously at a high speed to see which interaction is potentially causing problems. PowerWave goes beyond standard power quality measurements; PowerWave’s fast data capture mode enables system dynamics to be characterized.

Waveforms for voltage and current are continuously captured for the specified time, and are displayed on screen in high detail; the power waveform is derived from the data. In addition, half-cycle RMS values for voltage, current, power and frequency can be stored and retrieved for analysis. This feature is particularly useful for testing of standby generation systems and UPS systems where reliable switch-on can be vital.

Power inverter efficiency
Power inverters take DC current and transform it into AC current, or vice versa. Solar generation systems usually include an inverter that takes the DC energy from the solar cells and converts it to useful AC power. Inverters can lose performance over time and need to be checked. By comparing the input power with the output power you can determine the system efficiency. The 430 series II can measure the efficiency of such inverters by simultaneously measuring the DC and AC power of a system to determine how much power is lost in the conversion process.

 

Fluke 434 Series II Power Quality Analyzer - Energy Loss Calculator

Unified Power Measurement
Fluke’s patented Unified Power Measurement system (UPM) provides the most comprehensive view of power available, measure:

  • Parameters of Classical Power (Steinmetz 1897) and IEEE 1459-2000 Power
  • Detailed Loss Analysis
  • Unbalance Analysis
These UPM calculations are used to quantify the fiscal cost of energy loss caused by power quality issues. The calculations are computed, along with other facility-specific information, by an Energy Loss Calculator that ultimately determines how much money a facility loses due to wasted energy.

 

Fluke 434 Series II Power Quality Analyzer - AutoTrend - Quickly see the trend

AutoTrend - Quickly see the trend
Unique AutoTrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.



Fluke 434 Series II Power Quality Analyzer - System Monitor, check performance against EN50160 with ease.

SystemMonitor - Check performance against EN50160 with ease
With a single push of a button, the unique System-Monitor gives you an overview of power system performance, and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits.


Fluke 434 Series II Power Quality Analyzer - System Monitor Overview

The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.

Fluke 434 Series II Power Quality Analyzer - Logger

Logging function allows you to customize measurement selections and provides instantaneous analysis of user-selectable parameters.

Fluke 434 Series II Power Quality Analyzer - Power and Energy Meter

Measure and record power (W), VA and VARs, PF and energy consumption.

Fluke 434 Series II Power Quality Analyzer - Harmonics

Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements


Product specifications


Model Measurement range Resolution Accuracy
Volt
Vrms (ac+dc) 435-II1 V to 1000 V phase to neutral 0.01 V ± 0.1% of nominal voltage****
Vpk
1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF)
1.0 > 2.8 0.01 ± 5 %
Vrms½ 435-II
0.1 V ± 0.2% of nominal voltage
Vfund 435-II
0.1 V ± 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc) i430-Flex 1x 5 A to 6000 A 1 A± 0.5% ± 5 counts
i430-Flex 10x0.5 A to 600 A 0.1 A± 0.5% ± 5 counts
1mV/A 1x5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Apk i430-Flex 8400 Apk 1 Arms ± 5 %
1mV/A 5500 Apk1 Arms ± 5 %
A Crest Factor (CF)
1 to 10 0.01 ± 5 %
Amps½ i430-Flex 1x 5 A to 6000 A 1 A ± 1% ± 10 counts
i430-Flex 10x0.5 A to 600 A0.1 A ± 1% ± 10 counts
1mV/A 1x 5 A to 2000 A 1A ± 1% ± 10 counts
1mV/A 10x0.5 A A to 200 A (ac only) 0.1 A± 1% ± 10 counts
Afund i430-Flex 1x 5 A to 6000 A 1 A ± 0.5% ± 5 counts
i430-Flex 10x 0.5 A to 600 A0.1 A ± 0.5% ± 5 counts
1mV/A 1x 5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Hz
Hz Fluke 435 @ 50 Hz nominal
42.500 Hz to 57.500 Hz
0.001 Hz

± 0.01 Hz
Fluke 435 @ 60 Hz nominal 51.000 Hz to 69.000 Hz
0.001 Hz

± 0.01 Hz
Power
Watts (VA, var) i430-Flex
max 6000 MW0.1 W to 1 MW± 1% ± 10 counts
1 mV/Amax 2000 MW 0.1 W to 1 MW± 1% ± 10 counts
Power factor (Cos j/DPF)
0 to 1 0.001 ± 0.1% @ nominal load conditions
Energy
kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts
Energy loss i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts Excluding line resistance accuracy
Harmonics
Harmonic order (n)
DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-harmonic order (n)
OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts %f 0.0 % to 100 %0.1 %± 0.1% ± n x 0.1 %
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 1000 V 0.1 V± 5% *
THD0.0 % to 100 % 0.1 %± 2.5 %
Amps %f 0.0 % to 100 %0.1 %± 0.1% ± n x 0.1%
%r 0.0 % to 100 % 0.1 %± 0.1% ± n x 0.4 %
Absolute 0.0 to 600 A 0.1 A± 5% ± 5 counts
THD0.0 % to 100 % 0.1 % ± 2.5 %
Watts %f or %r 0.0 % to 100 %0.1 %± n x 2%
AbsoluteDepends on clamp scaling and V nominal ± 5% ± n x 2 % ± 10 counts
THD 0.0 % to 100 % 0.1 %± 5 %
Phase Angle
-360° to +0° ± n x 1°
Flicker
Plt, Pst, Pst(1min) Pinst
0.00 to 20.00 0.01 ± 5 %
Unbalance
Volts% 0.0 % to 20.0 % 0.1 % ± 0.1 %
Amps% 0.0 % to 20.0 % 0.1% ± 1 %
Mains signaling
Threshold levels
Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling frequency
60 Hz to 3000 Hz 0.1 Hz
Relative V%
0 % to 100 % 0.10 % ± 0.4 %
Absolute V3s (3 second avg.)
0.0 V to 1000 V 0.1 V ± 5 % of nominal voltage

General specifications

CaseDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
DisplayBrightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-time clockTime and date stamp for Trend mode, Transient display, System Monitor and event capture

Environmental

Operating temperature0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature-20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95% RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
Maximum operating altitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC)EN 61326 (2005-12) for emission and immunity
Interfacesmini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
WarrantyThree years (parts and labor) on main instrument, one year on accessories


What's Included:

  • Fluke soft carrying case
  • Fluke i430s 4x 3000A flexible current clamps, CAT IV 600 V rated
  • Fluke TLS430 5 Test leads, 4 black, 1 green
  • Fluke BC430 Battery Charger Eliminator
  • FlukeView Software SW43W
  • Fluke PowerLog Software
  • Fluke OC4USB Optical Cable for USB
  • Fluke WC100 Color localization set
  • Getting Started printed
  • User Manual (CD-ROM)
The Good:


The Bad:


The Bottom Line:

Full Review

  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools – even while background recording continues
  • Highest safety rating in the industry – 600V Cat IV / 1000V CAT III
  • Automatic transient mode captures 200kHz waveform data on all phases simultaneously--up to 6kV
  • Measure all three phases and neutral with included 4 current probes
  • AutoTrend: every measurement you see is always automatically recorded, without any setup
  • System-Monitor: Up to seven power quality parameters on one screen according to EN50160
  • Inrush mode for troubleshooting nuisance circuit breaker tripping
  • Rugged, handheld troubleshooter with Fluke 3 year warranty
  • Seven hours operating time per charge on NiMH battery pack
  • View graphs and generate reports with included analysis software

Fluke 435 Only Features:

  • Fully Class A Compliant – with 0.1% voltage accuracy, test according to the stringent international IEC 61000-4-30 Class A standard
  • Logger function - Configure for any test condition with memory up to 400 parameters at user defined intervals
  • New Fluke PowerLog software – Easily view logged data and generate reports
  • Flexible current probes included – these new 6000A CAT IV are instrument powered (no more batteries)
  • Mains Signaling - Measure interference from ripple control signals at specific frequencies
  • Rugged roller carry case protects the 435 during shipping and transportation
  • Double the memory for expanded logging time


Enhancements:

  • Expanded voltage configurations with 2 and 2.5 element modes
  • Supports GPS time synchronization according to IEC61000-4-30 via optional Fluke GPS430 module
  • Phase angle resolution improved to 0.1º resolution and referenced to L1/A voltage
  • Phase rotation indicator provides clear indication of the phase rotation direction to determine correct connections.

AutoTrend - Quickly see the trend
Unique AutoTrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or interval times, or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral. And you can analyze the trends using the cursors and zoom function – even while background recording continues.

AutoTrend automatically records all displayed parameters in the background.

SystemMonitor - Check performance against EN50160 with ease
With a single push of a button, the unique System-Monitor gives you an overview of power system performance, and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits.

The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.

Logging function allows you to customize measurement selections and provides instantaneous analysis of user-selectable parameters. Measure and record power (W), VA and VARs. The 434 adds the ability to record energy consumption. Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements
Technical Data
Inputs
Number:4 voltage and current (3 phases + neutral)
Maximum voltage:1000 Vrms (6 kV peak)
Maximum sampling speed:200 kS/s on each channel simultaneously
Volt/Amps/Hertz
Vrms (AC + DC)
Measurement range:1 ... 1000 V
Accuracy:0.1% of Vnom


Vpeak
Measurement range:1 ... 1400 V
Accuracy:5% of Vnom


Crest factor, voltage
Measurement range:1.0 ... > 2.8
Accuracy:±5%


Arms (AC + DC)
Measurement range:0 ... 20 kA
Accuracy:±0.5% ± 5 counts


Apeak
Measurement range:0 ... 5.5 kA
Accuracy:5%


Crest factor, A
Measurement range:1 ... 10
Accuracy:±5%


Hz 50 Hz nominal
Measurement range:42.50 ... 57.50 Hz
Accuracy:±0.01 Hz
Dips and swells
Vrms (AC+DC) ²
Measurement range:0.0% … 100% of Vnom
Accuracy:±0.2% of nominal voltage


Arms (AC+DC) ²
Measurement range:0 ... 20 kA 
Accuracy:±1% ± 5 counts
Harmonics
Harmonic (interharmonic) (n)
Measurement range:DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7


Vrms
Measurement range:0.0 … 1000 V
Accuracy:±0.05% of nominal voltage


Arms
Measurement range:0.0 … 4000 mV x clamp scaling
Accuracy:±5% ± 5 counts


Watts
Measurement range:Depends on clamp scaling and voltage
Accuracy:±5% ± n x 2% or reading, ± 10 counts


DC voltage
Measurement range:0.0 … 1000 V
Accuracy:±0.2% of nominal voltage


THD
Measurement range:0.0 … 100.0%
Accuracy:±2.5% V and A (± 5% Watt)


Hz
Measurement range:0 … 3500 Hz
Accuracy:± 1 Hz


Phase angle
Measurement range:-360º ... +360º
Accuracy:± n × 1.5º
Power and energy
Watt, VA, VAR
Measurement range:1.0 … 20.00 MVA¹
Accuracy:±1% ± counts


kWh, kVAh, kVARh
Measurement range:00.00 …200.0 GVAh¹
Accuracy:± 1.5% ± 10 counts


Power Factor/ Cos Ф / DPF
Measurement range:0…1
Accuracy:± 0.03
Flicker
Pst (1 min), Pst, Plt, PF5
Measurement range:0.00 … 20.00
Accuracy:±5%
Unbalance
Volts
Measurement range:0.0 … 5.0%
Accuracy:±0.5%


Current
Measurement range:0.0 … 20%
Accuracy:± 1%
Transient Capture
Volts
Measurement range:±6000 V
Accuracy:±2.5% of Vrms
Minimum detect duration5 µs (200kS/s sampling)
Inrush mode
Arms (AC+DC)
Measurement range:0.000 … 20.00 kA¹
Accuracy:±1% of meas ± 5 counts


Inrush duration (selectable)
Measurement range:7.5 s ... 30 min
Accuracy:±20 ms (Fnom = 50 Hz)
Autotrend recording
Sampling:5 readings/sec continuous sampling per channel
Memory:1800 min, max and avg points for each reading
Recording time:Up to 450 days
Zoom:Up to 12x horizontal zoom
Memory
Screens & data:50, shared memory divided between logging, screens and data sets
Notes
¹Depending on clamp scaling
²Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Environmental Specifications
Operating Temperature

0 ºC to +50 ºC

Safety Specifications
Safety

EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01

Mechanical & General Specifications
Size

256 x 169 x 64 mm
Weight

1.1 kg
Battery Life
Rechargeable NiMH pack (installed):>7 hours
Battery charging time:4 hours typical
Shock & Vibration
Shock:30 g
Vibration:3 g according to MIL-PRF-28800F Class 2
Case

Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)
Warranty

3 years
Perform custom analysis and create reports with included software. Measurement data can also be exported to common spreadsheet programs.














Generate reports and view graphs with Fluke Power Log Software


Designed to quickly view recorded data, the included Power Log software displays all recorded parameters on interactive trends.  Generate a professional report with the ‘Report Writer’ function, or copy and paste images into report document manually.





























FlukeView Power Quality Analyzer Software
(SW43W) offers you simple mouse-controlled tools to work with your Power Quality Analyzer.

The FlukeView software communicates with your Power Quality Analyzer via the optically isolated OC4USB adapter/cable connected to the USB of the PC.  The OC4USB driver creates a virtual COM port. FlukeView will handle the USB port as a COM port.

  • Capture measurement screens for professional-looking reports
  • Log readings to your computer disk drive
  • Works with Windows® word processing, spreadsheet and analysis software
  • Windows® 3.1, Windows® 95 and Windows® NT compatible

Note:

The optional RS-232 adapter/cable PM9080 allows you to communicate via a COM port of your PC.
No user reviews available.
Recommended Accessories
The Fluke 435-II Three Phase Power Quality Analyzer Kit has 26 recommended accessories.        Click to show all accessories


Cases
Name Price Quantity
Fluke C1600 Meter and Accessories Gear Box $51.95
Cases
Name Price Quantity
Fluke C435 Hard Rolling Case $512.95
Communications
Current Probes
Current Probes
Current Probes
GPS
Name Price Quantity
Fluke GPS430 Time Synchronization Module $1,343.95
Lighting
Name Price Quantity
Fluke L206 Deluxe LED Hat Light $39.95
Miscellaneous
Name Price Quantity
Fluke WC100 Color Localization Set $28.94
Power
Test Leads
Unassigned

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Phone
Message
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.