Fluke 1735 Three Phase Power Logger

Part Number:
FE 1735
In Stock?
Yes! Available up to 3 units

Quantity

Price:
$3186.95 USD (change)

 

Shipping Information:

Ships in 2 - 4 Days
Arrives:
Feb 10-
Feb 16
Max of 3 units
$62.50
Fast: Ships today*
Arrives:
Feb 09
Max of 3 units
$87.50
Fastest: Overnight
Arrives:
Feb 08
Max of 3 units
$115.00
Want a great deal on this Fluke 1735?

Are you ready to buy this product but need a better price? No problem - you decide the price! Tell us how much you are willing to pay for this product and we'll try to make it work.

First Name:
Last Name:
Phone:
Email Address:
Offer Price:
Comments
Consider Used/Demo:
Check this box if you are willing to consider ex-sales demonstration items.
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

Enter Passcode:

Limited time promotion

The Fluke 1735 Three Phase Power Logger is the idea tool for electrical load studies, energy consumption testing and general power quality logging.

The Fluke 1735 logs most critical three-phase power parameters plus harmonics and captures voltage events. The Fluke 1735 can log rms voltage, rms current, phase angle, voltage events, voltage and current THD, voltage and current harmonics up to the 50th, active power, reactive power, power factor, active energy, reactive energy, and more.

With memory for up to 45 days of data, the 1735 can uncover intermittent or hard-to-find issues.

Set up the 1735 in seconds, with the included flexible current probes and color display.

The four current probes are connected with one plug, the instrument automatically detects, scales and powers the probes. These variable range current probes are easily set to 15 A, 150 A, or 3000 A for high accuracy in nearly any application.

The voltage connections are single leads, enabling easy and quick setups. The color screen provides instant confirmation that connections are correct, and then logging begins when you press the RECORD button.

Applications:

  • Load studies - verify electrical system capacity before adding loads
  • Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices
  • Harmonics measurements - uncover harmonic issues that can damage or disrupt critical equipment
  • Voltage event capture - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
See the additional tabs above this content for features, specifications, virtual demos and other documents and list of what's included with the Fluke 1735 three phaser power logger.

What's Included:
• 4 flexible current probes (15 A/150 A/3000 A)
• Power Log software
• Voltage leads and clips
• Color localization set
• PC interface cable
• International ac adapter (115/ 30 V, 50/60 Hz)
• Printed English manual
• Multi-language manual CD
• Soft carry case
The Good:


The Bad:


The Bottom Line:

Full Review

The 1735 offers many features and benefits to the user:
  • Record power and associated parameters for up to 45 days
  • Monitor maximum power demand over user-defined averaging periods
  • Prove the benefit of efficiency improvements with energy consumption tests
  • Measure harmonic distortion caused by electronic loads
  • Improve reliability by capturing voltage dips and swells from load switching
  • Easily confirm instrument setup with color display of waveforms and trends
  • Measure all three phases and neutral with included 4 flexible current probes
  • View graphs and generate reports with included Power Log software
  • Compact, rugged design with IP65 case, 600 V CAT III and two-year warranty
The 1735 can be used in three phase electrical systems
  • Up to 480V WYE and 870V Delta
  • Current measurement up to 3000A with the included 3000A flex CT's
  • It records Harmonics to the 50th, and logs Power Quality events like:
  • Voltage Sags and Swells, interuptions  with 10 mS resolution
  • Energy (kWh and mWh) Frequency and Power Factor Measurements
See the attached brochure (click Icon above) for complete brochure and spec sheet.
General
Display:¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality:Developed, designed and manufactured according to DIN ISO 9001
Memory:4 MB Flash memory, 3.5 MB for measuring data
Interface:RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate:10.24 kHz
Line frequency:50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply:NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Operation time with battery:Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions:240 mm x 180 mm x 110 mm
Weight:1.7 kg, including battery
Ambient conditions
Working temperature range:-10 °C to +50 °C
Storage temperature range:-20 °C to +60 °C
Operating temperature range:0 °C to +40 °C
Reference temperature range:23 °C ± 2 °C
Note:The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient:± 0.1 % of the measured value per °C from the reference
Intrinsic error:Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error:Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class:C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
Housing:Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMC
Emission:IEC/EN 61326-1:1997 class B
Immunity:IEC/EN 61326-1:1997
Safety
Safety:IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection:IP65; EN60529 (refers only to the main housing without the battery compartment)

RMS values are measured with a 20 ms resolution.
V-rms wye measurement
Measuring range:57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
Intrinsic error:± (0.2% of measured value + 5 digits)
Operating error:± (0.5% of m. v. + 10 digit)
Resolution:0.1 V
V-rms delta measurement
Measuring range:100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
Intrinsic error:± (0.2% of m. v. + 5 digit)
Operating error:± (0.5 % of m. v. + 10 digit)
Resolution:0.1 V
A-rms measurement
Flexi set I ranges:15 A/150 A/3000 A rms (at sine)
Current clamp ranges:1 A/10 A
Resolution:0.01 A
Ranges150 A/3000 A and 1 A/10 A
Intrinsic error:± (0.5 % of m. v. + 10 digit)
Operating error:± (1 % of m. v. + 10 digit)
Ranges15 A
Intrinsic error:± (0.5 % of m. v. + 20 digit)
Operating error:± (1 % of m. v. + 20 digit)

The errors of the current probes are not considered.

By using Flexi-Set
Flexi Set measuring error:± (2% of m. v. + 10 digit)
Position influence:± (3 % of m. v. + 10 digit)
CF (typical):2.83
Note:When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
Measuring range:see V rms and A rms measurement

Power errors are calculated by adding the errors of voltage and current

Additional error due to power factor PF

Specified error x (1-[PF])

Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error:± (0.7 % of m.v. +15 digit)
Resolution:1 kW
Operating error:± (1.5 % of m.v. + 20 digit)

Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error:± (0.7 % of m.v. +15 digit)
Resolution:1 W to 10 W
Operating error:± (1.5 % of m.v. + 20 digit)

The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)
Intrinsic error:± (0.7 % of m.v.+ F variation error* + 15 digit)
Resolution:1 W to 10 W
Operating error:± (1.5 % of m.v. + F variation error* + 20 digit)

*Frequency variation error
PF (Power factor)
Range:0.000 to 1.000
Resolution:0.001
Accuracy:±1 % of full scale
Frequency measurement
Measuring range:46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error:± (0.2 % of m. v. + 5 digit)
Operating error:± (0.5 % of m. v.+ 10 digit)
Resolution:0.01 Hz
Harmonics
Measuring range:To 50th harmonic (< 50 % of nom)
Accuracy
Vm, Im, THDV, THDI:IEC 61000-4-7:2002, Class II
Vm ≥ 3% Vn:± 5% Vm
Vm < 3 % Vnom:±0.15% Vnom
Im ≥ 10 % Inom:± 5% Im
Im < 10 % Inom:± 0 5% Inom
THDV:for THD < 3% ± 0.15% at Vnom
for THD ≥ 3% ± 5% at Vnom
THDI:for THD < 10% ± 0.5% at Inom
for THD ≥ 10% ± 5% at Inom
Vnom:Normal voltage range
Inom:Nominal current range

Vm and Im are measured values of harmonic m
Events

Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error:± (1% of m.v. + 10 digit)
Operating error:± (2% of m.v. + 10 digit)
Resolution:0.1 V

Generate reports and view graphs with Fluke Power Log Software

Designed to quickly view recorded data, the included Power Log software displays all recorded parameters on interactive trends.  Generate a professional report with the ‘Report Writer’ function, or copy and paste images into report document manually.

  • Easy-to-use tabbed window format allows quick data evaluation.
  • One-step download and display capability
  • Waveform, harmonics, and trend download
  • Simple data export to other applications
  • View recorded data in simple graphs and tables.
  • Easily customize the report.