The AEMC 8230 Single Phase Power Quality Analyzer is easy-to-use, compact and shock-resistant. It is intended for technicians and engineers to measure and carry out diagnostic work and power quality work on single- or three-phase balanced load networks.
Users are able to obtain instant waveforms of an electrical network’s principal characteristics, and also monitor their variation over a period of time. The multi-tasking measurement system simultaneously handles all the measurement functions and waveform display of the various magnitudes, detection, continuous recordings and their display without any constraints.
The AEMC 8230 Single Phase Power Quality Analyzer PowerPad Jr. is available in complete kits that include your choice of current transformer below.
For a similar product that features temperature and RPM without the real-time waveform display, see the AEMC 8230 sister product, AEMC 8220
Applications:
- Motor start-up analysis
- Verification of power distribution circuits
- Measurement and recording of power system quality (kW, VA, VAR)
- Energy metering (kVAh, VARh, kWh)
- In-plant troubleshooting of power distribution panels and individual machinery
- Determine harmonic problems originating from source or load
Purchase the AEMC 8230 alone or with the available Current Transformers listed in the box below:
What's Included:
- Set of two 10 ft (3m) color-coded leads (red/black) with alligator clips
- DataView® software FREE for data storage, real-time waveform display, analysis and report generation
- Optical USB cable
- US 110V power adapter
- Set of six 1.2V AA NiMH rechargeable batteries
- Carrying bag
- Product warranty card and user manual
The Bad:
The Bottom Line:
Full Review
- Measures up to 660Vrms or VDC
- Measures up to 6500AAC or 1400ADC (probe dependent)
- Displays Min, Max and Average Volts and Amps, Crest Factor, Peak value and K-Factor
- Calculates and displays Watts, VARs and VA, Power Factor and Displacement Power Factor for single-phase and balanced three-phase
- Displays total harmonic distortion (THD-F and THD-R) for voltage and current
- Displays individual harmonic values and % for Volts and Amps through the 50th harmonic
- Captures, displays and stores inrush current waveforms and statistics
- Stores up to eight screen captures
- Stores up to 1MB of trend recorded data<li>
- Configurable from DataView® software or front panel
- Download stored data to DataView® software via optical with isolated USB port
- Captures up to 4096 alarm events using up to 10 different thresholds
- Displays and records up to 17 different power quality parameters
- Includes DataView® software FREE.
Large Color Display






|
SPECIFICATIONS
|
|
|||
|
MODEL |
|
8230 |
||
|
ELECTRICAL |
|
|||
|
Voltage (TRMS) |
Phase-to-Phase:
660V Phase-to-Neutral: 600V |
|||
|
Current (TRMS) |
MN Clamp: 5mA to
120A or 2 to 240A MR Clamp: 10 to
1000AAC, 10 to 1400ADC SR Clamp: 3 to 1200A AmpFlex®: 10 to
6500A(1) |
|||
|
Frequency (Hz) |
40 to 70Hz |
|||
|
Other Measurements |
kW,
kVAR, PF, DPF, kWh, kVARh, kVAh, K-Factor, |
|||
|
|
Flicker,
Harmonic Phase Shift, Phase Rotation |
|||
|
Harmonics |
THD-R, THD-F, V, A,
VA |
|||
|
|
1st to 50th,
Direction, Sequence |
|||
|
Sampling Frequency |
256 samples |
/ |
cycle
|
|
|
Data Storage |
1.5MB
partitioned for waveforms, alarms and trend recording |
|||
|
Power Source |
NiMH
AA rechargeable battery pack AC Supply: 120/230VAC (50/60Hz) |
|||
|
|
≥8
hrs with display on ≥40 hrs with display off (recording mode) |
|||
|
MECHANICAL |
|
|||
|
|
Optically isolated
USB |
|||
|
Display |
1/4 VGA (320 x 240)
color LCD |
|||
|
Dimensions |
8.3 x 4.3 x
2.4" (211 x 108 x 60mm) |
|||
|
Weight |
1.9 lbs (0.88kg) |
|||
|
Safety Rating |
EN 61010, 600V Cat. III, Pollution Degree 2 |
|||
|
(1)Crest factor at 6500 = 1 |
||||
DataView Professional is a full-featured data collection, analysis and reporting software package which includes great flexibility for customization of views, templates and reports to meet the most demanding requirements, combined with the ability to present trend graphs, waveforms and data in real time on a PC.
Requirements:- Windows XP /
Windows Vista / Windows 7 (32/64 bit)
- 256MB of RAM for Windows XP
- 1GB of RAM for Windows Vista & Windows 7 (32 bit)
- 2GB of RAM for Windows Vista
& Windows 7 (64 bit)
- 80MB of hard disk space (200MB recommended )
- CD-ROM drive
Configure all functions of the PowerPad® Jr.
- Display and analyze real-time data on your PC
- Configure all PowerPad® Jr. functions and parameters from your PC
- Customize views, templates and reports to your exact needs
- Create and store a complete library of configurations that can be uploaded to the PowerPad® Jr. as needed
- Zoom in and out and pan through sections of the graph to analyze the data
- Download, display and analyze recorded data
- Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms
- Print reports using standard or custom templates you design