AEMC 4620 Digital Ground Resistance Tester

Part Number:
AEMC 4620
In Stock?
Stock may be available
please call (877)766-5412 to confirm

Quantity

Price:
$1095.00 USD (change)

 

The AEMC 4620 Digital Ground Resistance Tester performs ground resistance and soil resistivity tests. This direct reading tester measures from 0 to 2000Ω, and is autoranging, so that it can automatically seek out the optimum measurement range.

Easy-to-use — simply connect the leads, Press-to-Measure and read the results. The large LCD (nearly 3/4" high characters) is easy-to-read, and also indicates low battery status, overrange and test lead shorts and lead reversals. Three LED indicators on the front panel continuously warn the user of measurement problems to ensure accurate and reliable tests.

The AEMC 4620 Digital Ground Resistance Tester is fuse protected up to 250VAC against accidental connection to live circuits. In the event of a system fault, it can withstand 250VAC with spikes of 3000VAC or 1000VDC.

The heavy-duty field case is sealed against dust and water when closed. The meter itself is self-contained within an inner case providing additional environmental and insulation protection. The test button is also sealed against the elements.

This tester is powered by eight, C cell batteries and will perform over 2000 - 15 second tests between battery replacement. The AEMC 4620 Ground Resistance Tester is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. The AEMC 4620 exceeds mechanical and safety specifications for shock, vibration and drop tests called out in IEC standards. Designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy.

See the AEMC 4620 sister product, the AEMC 4630

Applications:

  • Three-Point measurements of resistance to ground of ground rods and grids. Three-Point measurements are generally used when the electrode or grid can be easily disconnected, if corrosion is suspected, or in circumstances where ground faults are unlikely to occur
  • Four-Point tests or soil resistivity measurements. Locating areas of lowest soil resistivity is essential for achieving an economical grounding installation
  • Touch potential measurements, an alternative to 3-Point tests in evaluating electrical safety. This test is recommended when the ground cannot be disconnected, where ground faults are highly likely to occur, or when the "footprint" of grounded equipment is comparable to the size of the ground to be tested.
  • Two-Point tests for continuity tests on bonding or on pre-established grounds. This test is commonly performed in urban environments where proper auxiliary electrode placement may be obscured by confined real estate. Measurements
    are referenced against a good local ground conductor.

Purchase the AEMC 4620 as a standalone unit or with the available kits below:

AEMC 4620 Kit -150ft - Digital Ground Resistance Tester Kit - 150ft
AEMC 4620 Kit -300ft - Digital Ground Resistance Tester Kit - 300ft
AEMC 4620 Kit -500ft - Digital Ground Resistance Tester Kit - 500ft

What's Included:

  • Meter
  • Eight C cell batteries
  • And user manual
The Good:


The Bad:


The Bottom Line:

Full Review


  • Measures soil resistivity (4-Point) method
  • Measures ground resistance (2- and 3-Point) Fall-of-Potential method
  • Step voltage tests and touch potential measurements
  • Auto-Ranging: automatically selects the optimum range
  • Designed to reject high levels of noise interference
  • Extremely simple to operate: connect - press - read
  • LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections
  • Battery powered
  • Rugged, dustproof and rainproof field case
  • Can also be used for continuity tests on bonding
  • Color-coded terminals


  • Range 20Ω; 200Ω; 2000Ω
    Measurement Range 0.00 to 19.99Ω; 20.0 to 199.9Ω; 200 to 1999Ω
    Resolution 10mΩ; 100mΩ; 1Ω
    Open Voltage ≤42V peak;  ≤42V peak;  ≤42V peak
    Resistance Measurement
    Frequency 128Hz square wave;  128Hz square wave;  128Hz square wave
    Test Current 10mA;  1mA;  0.1mA
    Accuracy ±2% of Reading ± 1ct; ±2% of Reading ± 1ct; ±2% of Reading ± 3cts
    Auxiliary Electrode Influence
    Max Res. in Current Circuit 3kΩ; 30kΩ; 50kΩ
    Max Res. in Voltage Circuit 50kΩ; 50kΩ; 50kΩ
    Response Time Approximately four to eight seconds for a stabilized measurement
    Withstanding Voltage 250VAC or 100VDC
    Power Source Eight C cell batteries Alkaline recommended
    Battery Life >2000 15-second measurements; LO BAT indication on LCD
    Fuse Protection 0.1A, >250V, 0.25 x 1.25"; 30kA Interrupt Capacity

    Product brochures

    Technical training

    Product manuals

    No user reviews available.
    Want to Purchase Everything Together? Kits and Bundles below:

    Recommended Accessories

    Have a Question?

    Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

    Name
    Email
    Phone
    Message
    In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

    Enter Passcode: