Fluke 353 True-rms 2000 A Clamp Meter

Part Number:
FE 353
In Stock?
Yes! Available up to 3 units

Quantity

Price:
$644.95 USD (change)

 

Shipping Information:

Ships in 2 - 4 Days
Arrives:
Feb 10-
Feb 16
Max of 3 units
$22.50
Fast: Ships today*
Arrives:
Feb 09
Max of 3 units
$59.50
Fastest: Overnight
Arrives:
Feb 08
Max of 3 units
$78.75
Want a great deal on this Fluke 353?

Are you ready to buy this product but need a better price? No problem - you decide the price! Tell us how much you are willing to pay for this product and we'll try to make it work.

First Name:
Last Name:
Phone:
Email Address:
Offer Price:
Comments
Consider Used/Demo:
Check this box if you are willing to consider ex-sales demonstration items.
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

Enter Passcode:

Industrial plants and large facilities often have equipment and installations that draw greater than 1000 A. As with other current measurements, it is not practical to disconnect the equipment to make a series of current measurements. The ability to check that an expensive system has been installed correctly, troubleshoot large loads, and make accurate measurements on UPS and Variable Frequency drives with noisy loads is also essential.  In industrial settings, compliance with NFPA 70E safety standards, while making measurements, is critical. Fluke has addressed this by designing this product to meet CAT IV 600 V and CAT III 1000 V ratings. 

Confidently take reliable readings with the Fluke 353 AC/DC True-rms Clamp Meter -  the tool of choice for high-current clamp-on amp meter measurements up to 2000 A.  The extra-wide jaw easily clamps around large conductors, typically found in high-current applications and the extra rugged design has an extra element of user protection when taking high-powered measurements.   

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.

Applications:

  • Industrial plants and facilities
  • Building maintenance, e.g. universities, hospitals, large offices, correctional institutions
  • Plant works, e.g. power, pharmaceutical, printing, automotive assembly
  • Manufacturing and process facilities
  • Refineries
  • Steel mills and other metal manufacturing plants
  • Large DC systems such as DC electroplating, or marine electrical systems

What's Included:

  • Fluke C43 Soft Carrying Case
  • 6 AA batteries
  • Users manual
  • 3 year warranty
The Good:


The Bad:


The Bottom Line:

Full Review


  • Reliably handle a wide range of high-current applications with 2000 AC/DC True-rms, 1400 A ac, and 2000 A dc
  • The large 2.3" (58 mm) jaw capacity is suitable for large, or multiple, conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings
Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 Ω Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits
Range: 4 kΩ Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits
Range: 40 kΩ Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits
Range: 400 kΩ Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)

On at ≤ 30 Ω

Off at ≥ 100 Ω
Frequency measurement
Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables

*Add 2 % to error spec for CF > 2

General specifications
Batteries

Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)

100 hours
Test leads

Rated to 1000 V
Weight

.814 kg (1.8 lb)
Jaw size

58 mm (2.28 in)
Dimensions (LxWxD)

300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating

IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Environmental specifications
Operating temperature

32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature

-4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity

0 to 95 % (non-condensing)
Operating altitude

2000 m
Storage altitude

10,000 m
IP rating

42 (indoor use only)
Drop test requirements

1 m
EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current: 0.1 % of reading per °C outside 22 °C to 24 °C
Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C
No user reviews available.
Recommended Accessories
The Fluke 353 True-rms 2000 A Clamp Meter has 1 recommended accessory.        Click to show all accessories


Test Leads
Name Price Quantity
Fluke TLK291 fused test probe set $65.95