The AEMC PQL 100 is a single phase Power Quality Logger designed to measure and log from a complete suite of electrical and power quality parameters.  It is accompanied by an easy-to-use report compliant software package with several report templates to facilitate your work.

The AEMC Power Quality Logger 100 is designed for North American commerical, industrial and residential applications, and is plugged into a standard AC receptacle.  In turn, any 120V load may be plugged into the Power Quality Logger:  office equipment, data equipment, machinery, compressors, heaters, motors, etc.

In industrial, commerical and residential sites, power quality is critical and may induce many problems, the causes of which need to be identified.  Outages reset clocks, timers and other sensitive devices; odd harmonics cause overheating in neutrals; harmonic energy causes motors and other devices to run improperly; spikes cause lighting to burn out prematurely; and surges and sags cause irritating flicker in lighting systems as well as inefficient machine operation.

The main advantage of the Power Quality Logger 100 is its ability to perform a wide variety of recording tasks with resolution and accuracy and easy, intuitive setup from a computer.  The PQL 100 measures, records and stores selected parameters in its memory.  Along with standard electrical parameters (V, A, W, Var, PF...), it also stores the Power Quality of the input waveforms (Harmonics, THD, Surge, Sag, K-Factor...).  The recorded information is retrieved from a computer via an RS-232 serial link using the report compliant DataView software package, which provides graphs, data and pre-configured reports.  With the DataView edition measurements and waveforms may be viewed in "real time" on a computer monitor and stored directly into the computer memory.  custom views and reports can then be created.

The Power Quality Logger 100 has a standard three-prong plug on back of unit and is line powered from the voltage source that it is connected to, with an internal battery to protect data integrity during power outages for up to one year.

Applications
  • Monitor power quality in North American commercial, industrial and residential application
  • Monitor power quality at computer workstations
  • Monitor power quality on laboratory equipment

The Good:


The Bad:


The Bottom Line:

Full Review


  • Portable, compact unit - plugs into standard US 120V outlets
  • Simple operation: Plug in, Record, Download & Read
  • Measures and stores electrical parameters: V, A, Hz & more
  • Measures and stores power parameters: W, VA, Var, Demand, Peak Demand & more
  • Measures and stores power quality parameters: Harmonics, THD (rms & fundamental), K-Factor & more
  • Automatically captures worst-case Surge, Sag & THD waveforms
  • High accuracy & resolution: 128 samples/cycle, 16 bit resolution
  • LEDs indicate mode of operation
  • Records up to 12 data channels
  • Powered from voltage input channel
  • Battery backup data integrity during power outages for up to 1 year. Configuration in non-volatile memory
  • Optically isolated RS-232 output for direct connection to a PC
  • EN 61010, 150V Cat. III
  • Includes DataView Analysis & Reporting Software

  • Voltage: 0 to 140 V
    • Resolution: 0.1V
    • Accuracy:+/- (0.3% of reading +0.3V)
  • Current: 0 to 15A (70A peak maximum)
    • Resolution: 0.01A
    • Accuracy:+/- (0.5% of reading +0.3A)
  • Channels: 1 Voltage, 1 Current
  • Sample rate: 128 per cycle per channel
  • Storage rate: 125 ms to 7 days

  • Display and analyze real-time data on your PC
  • Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration and more
  • Customize views, templates and reports to your exact needs
  • Create and store a complete library of configurations that can be uploaded to the logger as needed
  • Zoom in and out and pan through sections of the graph to analyze recorded data
  • Display real-time data on your PC and download previously recorded data
  • Display waveforms, trend graphs, harmonic spectrums and text summaries
  • Display surge and sag events in high-resolution waveforms and as tabular listings
  • Print reports using standard or custom templates you design


Minimum System Requirements:

  • Windows 98/2000/ME/XP
  • 128MB of RAM (256MC recommended) Windows 98/2000/ME
  • 256MB of RAM for Windows XP
  • 35MB of Hard Disk Space (200MB recommended)
  • CD Rom drive





Configure your logger from your computer. Select record length, sample rate, channel information to be recorded and more.











A comprehensive set of tools lets you customize templates and reports to your specific needs.








View data in real time on your PC. Customize the layout to include what's important to you.











Exceedence Report Trend Summary Report















VoltScreen












No user reviews available.
Recommended Accessories
The AEMC PQL 100 Power Quality Analyzer has 1 recommended accessory.        Click to show all accessories


Cases
Name Price Quantity
AEMC Soft Carrying Pouch $26.00

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Phone
Message
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

Enter Passcode: